.TL
|
||
|
The ACK Modula-2 Compiler
|
||
|
.AU
|
||
|
Ceriel J.H. Jacobs
|
||
|
.AI
|
||
|
Department of Mathematics and Computer Science
|
||
|
Vrije Universiteit
|
||
|
Amsterdam
|
||
|
The Netherlands
|
||
|
.AB no
|
||
|
.AE
|
||
|
.NH
|
||
|
Introduction
|
||
|
.PP
|
||
|
This document describes the implementation-specific features of the
|
||
|
ACK Modula-2 compiler. It is not intended to teach Modula-2 programming.
|
||
|
For a description of the Modula-2 language, the reader is referred to [1].
|
||
|
.PP
|
||
|
The ACK Modula-2 compiler is currently available for use with the VAX,
|
||
|
Motorola MC68020, Motorola MC68000,
|
||
|
PDP-11, and Intel 8086 code-generators.
|
||
|
For the 8086, MC68000, and MC68020,
|
||
|
floating point emulation is used. This is made available with the \fI-fp\fP
|
||
|
option, which must be passed to \fIack\fP[4,5].
|
||
|
.NH
|
||
|
The language implemented
|
||
|
.PP
|
||
|
This section discusses the deviations from the Modula-2 language as described
|
||
|
in the "Report on The Programming Language Modula-2", as it appeared in [1],
|
||
|
from now on referred to as "the Report".
|
||
|
Also, the Report sometimes leaves room for interpretation. The section numbers
|
||
|
mentioned are the section numbers of the Report.
|
||
|
.PP
|
||
|
Basically, the compiler recognizes the language as described in [1], and
|
||
|
most of [2], for backwards compatibility. It warns the user for old-fashioned
|
||
|
constructions (constructions that [1] does not allow).
|
||
|
If the \fI-Rm2-3\fP option (see [6]) is passed to \fIack\fP, this backwards
|
||
|
compatibility feature is disabled. Also, it may not be present on some
|
||
|
smaller machines, like the PDP-11.
|
||
|
.NH 2
|
||
|
Syntax (section 2)
|
||
|
.PP
|
||
|
The syntax recognized is that of the Report, with some extensions to
|
||
|
also recognize the syntax of an earlier definition, given in [2].
|
||
|
Only one compilation unit per file is accepted.
|
||
|
.NH 2
|
||
|
Vocabulary and Representation (section 3)
|
||
|
.PP
|
||
|
The input "\f510..\fP" is parsed as two tokens: "\f510\fP" and "\f5..\fP".
|
||
|
.PP
|
||
|
The empty string \f5""\fP has type
|
||
|
.DS
|
||
|
.ft 5
|
||
|
ARRAY [0 .. 0] OF CHAR
|
||
|
.ft P
|
||
|
.DE
|
||
|
and contains one character: \f50C\fP.
|
||
|
.PP
|
||
|
When the text of a comment starts with a '\f5$\fP', it may be a pragma.
|
||
|
Currently, two pragmas exist:
|
||
|
.DS
|
||
|
.ft 5
|
||
|
(*$F (F stands for Foreign) *)
|
||
|
(*$R[+|-] (Runtime checks, on or off) *)
|
||
|
.ft P
|
||
|
.DE
|
||
|
The Foreign pragma is only meaningful in a \f5DEFINITION MODULE\fP,
|
||
|
and indicates that this
|
||
|
\f5DEFINITION MODULE\fP describes an interface to a module written in another
|
||
|
language (for instance C, Pascal, or EM).
|
||
|
Runtime checks are: range-checks, checks when assigning CARDINALS to INTEGERS
|
||
|
and vice versa, and checks that FOR-loop control-variables are not changed
|
||
|
in the body of the loop.
|
||
|
.PP
|
||
|
Constants of type \f5LONGINT\fP are integers with a suffix letter \f5D\fP
|
||
|
(for instance \f51987D\fP).
|
||
|
Constants of type \f5LONGREAL\fP have suffix \f5D\fP if a scale factor is missing,
|
||
|
or have \f5D\fP in place of \f5E\fP in the scale factor (f.i. \f51.0D\fP,
|
||
|
\f50.314D1\fP).
|
||
|
This addition was made, because there was no way to indicate long constants,
|
||
|
and also because the addition was made in Wirth's newest Modula-2 compiler.
|
||
|
.NH 2
|
||
|
Declarations and scope rules (section 4)
|
||
|
.PP
|
||
|
Standard identifiers are considered to be predeclared, and valid in all
|
||
|
parts of a program. They are called \fIpervasive\fP.
|
||
|
Unfortunately, the Report does not state how this pervasiveness is accomplished.
|
||
|
However, page 87 of [1] states: "Standard identifiers are automatically
|
||
|
imported into all modules". Our implementation therefore allows
|
||
|
redeclarations of standard identifiers within procedures, but not within
|
||
|
modules.
|
||
|
.NH 2
|
||
|
Constant expressions (section 5)
|
||
|
.PP
|
||
|
Each operand of a constant expression must be a constant:
|
||
|
a string, a number, a set, an enumeration literal, a qualifier denoting a
|
||
|
constant expression, a typetransfer with a constant argument, or
|
||
|
one of the standard procedures
|
||
|
\f5ABS\fP, \f5CAP\fP, \f5CHR\fP, \f5LONG\fP, \f5MAX\fP, \f5MIN\fP, \f5ODD\fP, \f5ORD\fP,
|
||
|
\f5SIZE\fP, \f5SHORT\fP, \f5TSIZE\fP, or \f5VAL\fP, with constant argument(s);
|
||
|
\f5TSIZE\fP and \f5SIZE\fP may also have a variable as argument.
|
||
|
.PP
|
||
|
Floating point expressions are never evaluated compile time, because
|
||
|
the compiler basically functions as a cross-compiler, and thus cannot
|
||
|
use the floating point instructions of the machine on which it runs.
|
||
|
Also, \f5MAX(REAL)\fP and \f5MIN(REAL)\fP are not allowed.
|
||
|
.NH 2
|
||
|
Type declarations (section 6)
|
||
|
.NH 3
|
||
|
Basic types (section 6.1)
|
||
|
.PP
|
||
|
The type \f5CHAR\fP includes the ASCII character set as a subset. Values range from
|
||
|
\f50C\fP to \f5377C\fP, not from \f50C\fP to \f5177C\fP.
|
||
|
.NH 3
|
||
|
Enumerations (section 6.2)
|
||
|
.PP
|
||
|
The maximum number of enumeration literals in any one enumeration type
|
||
|
is \f5MAX(INTEGER)\fP.
|
||
|
.NH 3
|
||
|
Record types (section 6.5)
|
||
|
.PP
|
||
|
The syntax of variant sections in [1] is different from the one in [2].
|
||
|
Our implementation recognizes both, giving a warning for the older one.
|
||
|
However, see section 2.
|
||
|
.NH 3
|
||
|
Set types (section 6.6)
|
||
|
.PP
|
||
|
The only limitation imposed by the compiler is that the base type of the
|
||
|
set must be a subrange type, an enumeration type, \f5CHAR\fP, or
|
||
|
\f5BOOLEAN\fP. So, the lower bound
|
||
|
does not have to be positive. However, if a negative lower bound is used,
|
||
|
the compiler gives a warning of the \fIrestricted\fP class (see the manual
|
||
|
page of the compiler).
|
||
|
.PP
|
||
|
The standard type \f5BITSET\fP is defined as
|
||
|
.DS
|
||
|
.ft 5
|
||
|
TYPE BITSET = SET OF [0 .. 8*SIZE(INTEGER)-1];
|
||
|
.ft P
|
||
|
.DE
|
||
|
.NH 2
|
||
|
Expressions (section 8)
|
||
|
.NH 3
|
||
|
Operators (section 8.2)
|
||
|
.NH 4
|
||
|
Arithmetic operators (section 8.2.1)
|
||
|
.PP
|
||
|
The Report does not specify the priority of the unary operators \f5+\fP or \f5-\fP:
|
||
|
It does not specify whether
|
||
|
.DS
|
||
|
.ft 5
|
||
|
- 1 + 1
|
||
|
.ft P
|
||
|
.DE
|
||
|
means
|
||
|
.DS
|
||
|
.ft 5
|
||
|
- (1 + 1)
|
||
|
.ft P
|
||
|
.DE
|
||
|
or
|
||
|
.DS
|
||
|
.ft 5
|
||
|
(-1) + 1
|
||
|
.ft P
|
||
|
.DE
|
||
|
I have seen some compilers that implement the first alternative, and others
|
||
|
that implement the second. Our compiler implements the second, which is
|
||
|
suggested by the fact that their priority is not specified, which might
|
||
|
indicate that it is the same as that of their binary counterparts.
|
||
|
And then the rule about left to right decides for the second.
|
||
|
On the other hand, one might argue that, since the grammar only allows
|
||
|
for one unary operator in a simple expression, it must apply to the
|
||
|
whole simple expression, not just the first term.
|
||
|
.NH 2
|
||
|
Statements (section 9)
|
||
|
.NH 3
|
||
|
Assignments (section 9.1)
|
||
|
.PP
|
||
|
The Report does not define the evaluation order in an assignment.
|
||
|
Our compiler certainly chooses an evaluation order, but it is explicitly
|
||
|
left undefined. Therefore, programs that depend on it, may cease to
|
||
|
work later.
|
||
|
.PP
|
||
|
The types \f5INTEGER\fP and \f5CARDINAL\fP are assignment-compatible with
|
||
|
\f5LONGINT\fP, and \f5REAL\fP is assignment-compatible with \f5LONGREAL\fP.
|
||
|
.NH 3
|
||
|
Case statements (section 9.5)
|
||
|
.PP
|
||
|
The size of the type of the case-expression must be less than or equal to
|
||
|
the word-size.
|
||
|
.PP
|
||
|
The Report does not specify what happens if the value of the case-expression
|
||
|
does not occur as a label of any case, and there is no \f5ELSE\fP-part.
|
||
|
In our implementation, this results in a runtime error.
|
||
|
.NH 3
|
||
|
For statements (section 9.8)
|
||
|
.PP
|
||
|
The Report does not specify the legal types for a control variable.
|
||
|
Our implementation allows the basic types (except \f5REAL\fP),
|
||
|
enumeration types, and subranges.
|
||
|
A runtime warning is generated when the value of the control variable
|
||
|
is changed by the statement sequence that forms the body of the loop,
|
||
|
unless runtime checking is disabled.
|
||
|
.NH 3
|
||
|
Return and exit statements (section 9.11)
|
||
|
.PP
|
||
|
The Report does not specify which result-types are legal.
|
||
|
Our implementation allows any result type.
|
||
|
.NH 2
|
||
|
Procedure declarations (section 10)
|
||
|
.PP
|
||
|
Function procedures must exit through a RETURN statement, or a runtime error
|
||
|
occurs.
|
||
|
.NH 3
|
||
|
Standard procedures (section 10.2)
|
||
|
.PP
|
||
|
Our implementation supports \f5NEW\fP and \f5DISPOSE\fP
|
||
|
for backwards compatibility,
|
||
|
but issues warnings for their use. However, see section 2.
|
||
|
.PP
|
||
|
Also, some new standard procedures were added, similar to the new standard
|
||
|
procedures in Wirth's newest compiler:
|
||
|
.IP \-
|
||
|
\f5LONG\fP converts an argument of type \f5INTEGER\fP or \f5REAL\fP to the types \f5LONGINT\fP or
|
||
|
\f5LONGREAL\fP.
|
||
|
.IP \-
|
||
|
\f5SHORT\fP performs the inverse transformation, without range-checks.
|
||
|
.IP \-
|
||
|
\f5FLOATD\fP is analogous to \f5FLOAT\fP, but yields a result of type
|
||
|
\f5LONGREAL\fP.
|
||
|
.IP \-
|
||
|
\f5TRUNCD\fP is analogous to \f5TRUNC\fP, but yields a result of type
|
||
|
\f5LONGINT\fP.
|
||
|
.NH 2
|
||
|
System-dependent facilities (section 12)
|
||
|
.PP
|
||
|
The type \f5BYTE\fP is added to the \f5SYSTEM\fP module.
|
||
|
It occupies a storage unit of 8 bits.
|
||
|
\f5ARRAY OF BYTE\fP has a similar effect to \f5ARRAY OF WORD\fP, but is
|
||
|
safer. In some obscure cases the \f5ARRAY OF WORD\fP mechanism does not quite
|
||
|
work properly.
|
||
|
.PP
|
||
|
The procedure \f5IOTRANSFER\fP is not implemented.
|
||
|
.NH 1
|
||
|
Compile time errors
|
||
|
.PP
|
||
|
The compile time error messages are intended to be self-explanatory,
|
||
|
and not listed here. The compiler also sometimes issues warnings,
|
||
|
recognizable by a warning-classification between parentheses.
|
||
|
Currently, there are 3 classifications:
|
||
|
.IP "(old-fashioned use)"
|
||
|
.br
|
||
|
These warnings are given on constructions that are not allowed by [1], but are
|
||
|
allowed by [2].
|
||
|
.IP (strict)
|
||
|
.br
|
||
|
These warnings are given on constructions that are supported by the
|
||
|
ACK Modula-2 compiler, but might not be supported by others.
|
||
|
Examples: functions returning structured types, SET types of subranges with
|
||
|
negative lower bound.
|
||
|
.IP (warning)
|
||
|
.br
|
||
|
The other warnings, such as warnings about variables that are never assigned,
|
||
|
never used, etc.
|
||
|
.NH 1
|
||
|
Runtime errors
|
||
|
.PP
|
||
|
The ACK Modula-2 compiler produces code for an EM machine as defined in [3].
|
||
|
Therefore, it depends on the implementation
|
||
|
of the EM machine for detection some of the runtime errors that could occur.
|
||
|
.PP
|
||
|
The \fITraps\fP module enables the use to install his own runtime error handler.
|
||
|
The default one just displays what happened and exits.
|
||
|
Basically, a trap handler is just a procedure that takes an INTEGER as
|
||
|
parameter. The INTEGER is the trap number. This INTEGER can be one of the
|
||
|
EM trap numbers, listed in [3], or one of the numbers listed in the
|
||
|
\fITraps\fP definition module.
|
||
|
.PP
|
||
|
The following runtime errors may occur:
|
||
|
.IP "array bound error"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "range bound error"
|
||
|
.br
|
||
|
Range bound errors are always detected, unless runtime checks are disabled.
|
||
|
.IP "set bound error"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
The current implementations detect this error.
|
||
|
.IP "integer overflow"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "cardinal overflow"
|
||
|
.br
|
||
|
This error is detected, unless runtime checks are disabled.
|
||
|
This message is also given on cardinal underflow.
|
||
|
.IP "real overflow"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "real underflow"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "divide by 0"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "divide by 0.0"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "undefined integer"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "undefined real"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "conversion error"
|
||
|
.br
|
||
|
This error occurs when assigning a negative value of type INTEGER to a
|
||
|
variable of type CARDINAL,
|
||
|
or when assigning a value of CARDINAL, that is > MAX(INTEGER), to a
|
||
|
variable of type INTEGER.
|
||
|
It is detected, unless runtime checking is disabled.
|
||
|
.IP "stack overflow"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
.IP "heap overflow"
|
||
|
.br
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
Might happen when ALLOCATE fails.
|
||
|
.IP "case error"
|
||
|
.br
|
||
|
This error occurs when non of the cases in a CASE statement are selected,
|
||
|
and the CASE statement has no ELSE part.
|
||
|
The detection of this error depends on the EM implementation.
|
||
|
All current EM implementations detect this error.
|
||
|
.IP "stack size of process too large"
|
||
|
.br
|
||
|
The current implementation limits the stack size of processes to 1024 bytes.
|
||
|
.IP "too many nested traps + handlers"
|
||
|
.br
|
||
|
This error can only occur when the user has installed his own trap handler.
|
||
|
It means that during execution of the trap handler another trap has occurred,
|
||
|
and that several times.
|
||
|
In some cases, this is an error because of overflow of some internal tables.
|
||
|
.IP "no RETURN from procedure function"
|
||
|
.br
|
||
|
This error occurs when a procedure function does not return properly
|
||
|
("falls" through).
|
||
|
.IP "illegal instruction"
|
||
|
.br
|
||
|
This error might occur when you use floating point operations on an
|
||
|
implementation that does not have floating point.
|
||
|
.NH 1
|
||
|
Calling the compiler
|
||
|
.PP
|
||
|
See [4,5,6] for a detailed explanation.
|
||
|
.NH 1
|
||
|
References
|
||
|
.IP [1]
|
||
|
Niklaus Wirth,
|
||
|
.I
|
||
|
Programming in Modula-2, third, corrected edition,
|
||
|
.R
|
||
|
Springer-Verlag, Berlin (1985)
|
||
|
.IP [2]
|
||
|
Niklaus Wirth,
|
||
|
.I
|
||
|
Programming in Modula-2,
|
||
|
.R
|
||
|
Stringer-Verlag, Berlin (1983)
|
||
|
.IP [3]
|
||
|
A.S.Tanenbaum, J.W.Stevenson, Hans van Staveren, E.G.Keizer,
|
||
|
.I
|
||
|
Description of a machine architecture for use with block structured languages,
|
||
|
.R
|
||
|
Informatica rapport IR-81, Vrije Universiteit, Amsterdam
|
||
|
.IP [4]
|
||
|
UNIX manual \fIack\fP(1)
|
||
|
.IP [5]
|
||
|
UNIX manual \fImodula-2\fP(1)
|
||
|
.IP [6]
|
||
|
UNIX manual \fIem_m2\fP(6)
|