The m68k2 back end is an EM code generator for the
|
|
Motorola MC68000. It defines an integer to be 16 bits
|
|
and a pointer to be 32 bits.
|
|
The m68k2 back end generates code for the ACK 68000 assembler.
|
|
(The mnemonics recognized by this assembler can be found in
|
|
"as/mach3.c").
|
|
|
|
Some parts of the back end are system dependent, i.e. they depend
|
|
on the kind of target 68000 system.
|
|
- The way to do a Unix system call may vary from system to system.
|
|
For every system call you need to have an assembly routine that
|
|
passes the arguments and the system call number to Unix.
|
|
These routines should be put in the library file "lib/tail_mon".
|
|
The distribution contains a tail_mon file tailored for
|
|
UniSoft Unix (see directory "libsys").
|
|
Beware that several Unix systems (e.g. UniSoft Unix) use 4-byte
|
|
integers, whereas the m68k2 back end produces code for 2-byte
|
|
integers. In this case all system calls having an "int" parameter
|
|
should convert their parameters to "long"s.
|
|
- Most systems require some sort of "test for enough stack space"
|
|
at the beginning of every procedure, to get around the "back up"
|
|
problem. E.g. UniSoft Unix requires a "tst.b N(sp)" instruction
|
|
This instruction is generated by the routines "prolog()" and
|
|
"save" in "cg/mach.c".
|
|
- The output of the ACK 68000 linker is an a.out file that
|
|
has a different format as an a.out file on your system. (As most
|
|
68000 systems have different a.out formats, there is no such thing
|
|
as "the" 68000 a.out format). So a program is needed to convert the
|
|
ACK a.out format to your a.out format (as defined in
|
|
"/usr/include/a.out.h"). The program "cv/cv.c" does
|
|
the job for UniSoft Unix. It probably need only be slightly
|
|
modified for your system.
|
|
If your target 68000 does not run Unix, but is e.g. a stand alone
|
|
68000, you will need a program to download the ACK a.out file.
|
|
The program "dl/dl.c" produces Intel Hex format on standard output
|
|
from an a.out file.
|
|
- The EM runtime start-off ("libsys/head_em.s") may have to be modified.
|
|
It should call the procedure __m_a_i_n with parameters (argc,argv,envp).
|
|
Usually, Unix will put these on top of the stack before starting
|
|
the program. Note, however, that for 4-byte systems Unix will provide
|
|
a 4-byte argc, while __m_a_i_n expects a 2-byte argc; so the value
|
|
must be shortened to 2 bytes.
|
|
|
|
|
|
The m68k2 code generator translates most EM instructions in line.
|
|
For some complex EM instructions it uses assembly routines (stored in the
|
|
library "libem/libem_s.a").
|
|
|
|
The generated code does not check for array bound errors, overflow in
|
|
arithmetic operations or division by zero (the latter will cause a hardware
|
|
trap).
|
|
|
|
The code generator has the following register conventions:
|
|
a7: stack pointer
|
|
a6: local base pointer
|
|
a0,a1,d0,d1,d2: scratch registers
|
|
(d0 is also used for 2/4 bytes function results;
|
|
d0 and d1 are used for 8 bytes function results)
|
|
a2-a5,d3-d7: register variables.
|