.TH MODULA\-2 1 "$Revision$"
 | 
						|
.ad
 | 
						|
.SH NAME
 | 
						|
Modula-2 \- ACK Modula-2 compiler
 | 
						|
.SH SYNOPSIS
 | 
						|
\fBack\fR \-m\fImach\fR files
 | 
						|
.br
 | 
						|
\fImach\fR files
 | 
						|
.SH INTRODUCTION
 | 
						|
This document provides a short introduction to the use of the ACK Modula-2
 | 
						|
compiler. It also
 | 
						|
mentions the location of definition modules for "standard" modules.
 | 
						|
.SH FILENAMES
 | 
						|
Usually, a Modula-2 program consists of several definition and implementation
 | 
						|
modules, and one program module.
 | 
						|
Definition modules must reside in files with names having a ".def" extension.
 | 
						|
Implementation modules and program modules must reside in files having a
 | 
						|
".mod" extension.
 | 
						|
.PP
 | 
						|
The name of the file in which a definition module is stored must be the same as
 | 
						|
the module-name, apart from the extension.
 | 
						|
.SH CALLING THE COMPILER
 | 
						|
The easiest way to do this is to let the \fIack\fR(1) program do it.
 | 
						|
So, to compile a program module "prog.mod", just call
 | 
						|
.nf
 | 
						|
	\fBack\fR \-m\fImach\fR prog.mod [ objects of implementation modules ]
 | 
						|
		or
 | 
						|
	\fImach\fR prog.mod [ objects of implementation modules ]
 | 
						|
.fi
 | 
						|
where \fImach\fR is one of the target machines of ACK.
 | 
						|
.PP
 | 
						|
To compile an implementation module, use the \-\fBc\fR flag
 | 
						|
to produce a ".o" file.
 | 
						|
Definition modules can not be compiled; the compiler reads them when they are
 | 
						|
needed. 
 | 
						|
.PP
 | 
						|
For more details on the \fIack\fR program see \fIack\fR(1).
 | 
						|
.SH DEFINITION MODULES
 | 
						|
"Standard" definition modules can be found in
 | 
						|
the directory \fB~em/lib/m2\fR.
 | 
						|
.PP
 | 
						|
When the compiler needs a definition module, it is first searched for
 | 
						|
in the current directory, then in the directories given to it by the
 | 
						|
\-\fBI\fR flag
 | 
						|
in the order given,
 | 
						|
and then in the directory mentioned above.
 | 
						|
.SH FLAGS
 | 
						|
The \fIack\fR(1) program recognizes (among others) the following
 | 
						|
flags, that are passed to the Modula-2 compiler:
 | 
						|
.IP \fB\-I\fIdirname\fR
 | 
						|
.br
 | 
						|
append \fIdirname\fR to the list of directories where definition modules
 | 
						|
are looked for. 
 | 
						|
.IP \fB\-I\fP
 | 
						|
don't look in
 | 
						|
the directory \fB~em/lib/m2\fR.
 | 
						|
.IP \fB\-M\fP\fIn\fP
 | 
						|
set maximum identifier length to \fIn\fR. The minimum value of \fIn\fR
 | 
						|
is 14, because the keyword "IMPLEMENTATION" is that long.
 | 
						|
.IP \fB\-n\fR
 | 
						|
do not generate EM register messages.
 | 
						|
The user-declared variables will not be stored into registers on the target
 | 
						|
machine.
 | 
						|
.IP \fB\-L\fR
 | 
						|
do not generate the EM \fBfil\fR and \fBlin\fR instructions that enable
 | 
						|
an interpreter to keep track of the current location in the source code.
 | 
						|
.IP \fB\-w\fR\fIclasses\fR
 | 
						|
suppress warning messages whose class is a member of \fIclasses\fR.
 | 
						|
Currently, there are three classes: \fBO\fR, indicating old-flashioned use,
 | 
						|
\fBW\fR, indicating "ordinary" warnings, and \fBR\fR, indicating
 | 
						|
restricted Modula-2.
 | 
						|
If no \fIclasses\fR are given, all warnings are suppressed.
 | 
						|
By default, warnings in class \fBO\fR and \fBW\fR are given.
 | 
						|
.IP \fB\-W\fR\fIclasses\fR
 | 
						|
allow for warning messages whose class is a member of \fIclasses\fR.
 | 
						|
.IP \fB\-g\fR
 | 
						|
produce a DBX-style symbol table.
 | 
						|
.IP \fB\-x\fR
 | 
						|
make all procedure names global, so that \fIadb\fR(1) understands them.
 | 
						|
.IP \fB\-Xs\fR
 | 
						|
make INTEGER ranges symmetric, t.i., MIN(INTEGER) = - MAX(INTEGER).
 | 
						|
This is useful for interpreters that use the "real" MIN(INTEGER) to
 | 
						|
indicate "undefined".
 | 
						|
.LP
 | 
						|
.SH SEE ALSO
 | 
						|
\fIack\fR(1), \fIem_m2\fR(6), \fIm2mm(1)\fR
 | 
						|
.SH FILES
 | 
						|
.IR ~em/lib/em_m2 :
 | 
						|
binary of the Modula-2 compiler.
 | 
						|
.SH DIAGNOSTICS
 | 
						|
All warning and error messages are written on standard error output.
 | 
						|