855 lines
25 KiB
Plaintext
855 lines
25 KiB
Plaintext
.\" $Header$
|
|
.TL
|
|
.de Sy
|
|
.LP
|
|
.IP \fBsyntax\fR 10
|
|
..
|
|
.de PU
|
|
.IP \fBpurpose\fR 10
|
|
..
|
|
.de RM
|
|
.IP \fBremarks\fR 10
|
|
..
|
|
The ABC compiler
|
|
.AU
|
|
Martin L. Kersten
|
|
.AI
|
|
Department of Mathematics and Computer Science.
|
|
.br
|
|
Vrije Universiteit
|
|
.AB
|
|
This manual describes the
|
|
programming language BASIC and its compiler
|
|
included in the Amsterdam Compiler Kit.
|
|
.AE
|
|
.SH
|
|
INTRODUCTION.
|
|
.LP
|
|
The BASIC-EM compiler is an extensive implementation of the
|
|
programming language BASIC.
|
|
The language structure and semantics are modelled after the
|
|
BASIC interpreter/compiler of Microsoft (tr), a detailed comparison
|
|
is provided in appendix A.
|
|
.LP
|
|
The compiler generates code for a virtual machine, the EM machine
|
|
[[ACM, etc]]
|
|
Using EM as an intermediate machine results in a highly portable
|
|
compiler and BASIC code.
|
|
The drawback of EM is that it does not directly reflect one particular
|
|
hardware design, which means that many of
|
|
the low level operations available within
|
|
BASIC are ill-defined or even inapplicable.
|
|
To mention a few, the peek and poke instructions are likely
|
|
to be behave errorneous, while line printer and tapedeck
|
|
primitives are unknown.
|
|
.LP
|
|
This manual is divided into three chapters.
|
|
The first chapter discusses the general language syntax and semantics.
|
|
Chapter two describes the statements available in BASIC-EM.
|
|
Chapter 3 describes the predefined functions,
|
|
ordered alphabetically.
|
|
Appendix A discusses the differences with
|
|
Microsoft BASIC. Appendix B describes all reserved symbols.
|
|
Appendix C lists the error messages in use.
|
|
.sp
|
|
Additional information about EM and the Amsterdam Compiler Kit
|
|
can be obtained from .... and found in ......
|
|
.SH
|
|
SyNTAX NOTATION
|
|
.LP
|
|
The conventions for syntax presentation are as follows:
|
|
.IP CAPS 10
|
|
Items are reserved words, must be input as shown
|
|
.IP <> 10
|
|
Items in lowercase letters enclosed in angular brackets
|
|
are to be supplied by the user.
|
|
.IP [] 10
|
|
Items are optional.
|
|
.IP \.\.\. 10
|
|
Items may be repeated any number of times
|
|
.IP {} 10
|
|
A choice between two or more alternatives. At least one of the entries
|
|
must be chosen.
|
|
.IP | 10
|
|
Vertical bars separate the choices within braces.
|
|
.LP
|
|
All punctuation must be included where shown.
|
|
.NH 1
|
|
GENERAL INFORMATION
|
|
.LP
|
|
The BASIC-EM compiler is designed for a UNIX based environment.
|
|
It accepts a text file with your BASIC program (suffix .b) and generates
|
|
an executable file, called a.out.
|
|
.LP
|
|
Should we call the preprocessor first?
|
|
.NH 2
|
|
LINE FORMAT
|
|
.LP
|
|
A BASIC program consists of a series of lines, starting with a
|
|
positive line number in the range 0 to 65529.
|
|
A line may consists of more then one physical line on your terminal, but must
|
|
is limited to 1024 characters.
|
|
Multiple BASIC statements may be placed on a single line, provided
|
|
they are separated by a colon (:).
|
|
.NH 2
|
|
CONSTANTS
|
|
.LP
|
|
The BASIC compiler character set is comprised of alphabetic
|
|
characters, numeric characters, and special characters shown below.
|
|
.DS
|
|
= + - * / ^ ( ) % # $ \\ _
|
|
! [ ] , . ; : & ' ? > < \\ (blanc)
|
|
.DE
|
|
.LP
|
|
BASIC uses two different types of constants during processing:
|
|
numeric and string constants.
|
|
.br
|
|
A string constant is a sequence of characters taken from the ASCII
|
|
character set enclosed by double quotation marks.
|
|
.br
|
|
Numeric constants are positive or negative numbers, grouped into
|
|
five different classes.
|
|
.IP "a) integer constants" 25
|
|
Whole numbers in the range of -32768 and 32767. Integer constants do
|
|
not contain decimal points.
|
|
.IP "b) fixed point constants" 25
|
|
Positive or negative real numbers, i.e. numbers with a decimal point.
|
|
.IP "c) floating point constants" 25
|
|
Real numbers in scientific notation. A floating point constant
|
|
consists of an optional signed integer or fixed point number
|
|
followed by the letter E (or D) and an optional signed integer
|
|
(the exponent).
|
|
The allowable range of floating point constants is 10^-38 to 10^+38.
|
|
.IP "d) Hex constants" 25
|
|
Hexadecimal numbers, denoted by the prefix &H.
|
|
.IP "d) Octal constants" 25
|
|
Octal numbers, denoted by the prefix &O.
|
|
.NH 2
|
|
VARIABLES
|
|
.LP
|
|
Variables are names used to represent values in a BASIC program.
|
|
A variable is assigned a value by assigment specified in the program.
|
|
Before a variable is assigned its value is assumed to be zero.
|
|
.br
|
|
Variable names are composed of letters, digits or the decimal point,
|
|
starting with a letter. Up to 40 characters are significant.
|
|
A variable name be be followed by any of the following type
|
|
declaration characters:
|
|
.IP % 5
|
|
Defines an integer variable
|
|
.IP ! 5
|
|
Defines a single precision variable (see below)
|
|
.IP # 5
|
|
Defines a double precision variable
|
|
.IP $ 5
|
|
Defines a string variable.
|
|
.LP
|
|
NOTE: Two variables with the same name but different type is
|
|
considered illegal (DONE?).
|
|
.LP
|
|
Beside single valued variables, values may be grouped
|
|
into tables or arrays.
|
|
Each element in an array is referenced by the array name and an index,
|
|
such a variable is called a subscripted variable.
|
|
An array has as many subscripts as there are dimensions in the array,
|
|
the maximum of which is 11.
|
|
.br
|
|
If a variable starts with FN it is assumed to be a call to a user defined
|
|
function.
|
|
.br
|
|
A variable name may not be a reserved word nor the name
|
|
of a predefined function.
|
|
A list of all reserved identifiers is included as Appendix ?.
|
|
.NH 2
|
|
EXPRESSIONS
|
|
.LP
|
|
BASIC-EM differs from Microsoft BASIC in supporting floats in one precision
|
|
only (due to EM).
|
|
All floating point constants have the same precision, i.e. 16 digits.
|
|
.LP
|
|
When necessary the compiler will convert a numeric value from
|
|
one type to another.
|
|
A value is always converted to the precision of the variable it is assigned
|
|
to.
|
|
When a floating point value is converted to an integer the fractional
|
|
portion is rounded.
|
|
In an expression all values are converted to the same degree of precision,
|
|
i.e. that of the most precise operand.
|
|
.br
|
|
Division by zero results in the message "Division by zero".
|
|
If overflow (or underflow) occurs, the "Overflow (underflow)" message is
|
|
displayed and execution is terminated (contrary to Microsoft).
|
|
.SH
|
|
Arithmetic
|
|
.LP
|
|
The arithmetic operators in order of precedence,a re:
|
|
.DS L
|
|
\^ Exponentiation
|
|
- Negation
|
|
*,/,\\,MOD Multiplication, Division, Remainder
|
|
+,- Addition, Substraction
|
|
.DE
|
|
The operator \\\\ denotes integer division, its operands are rounded to
|
|
integers before the operator is applied.
|
|
Modulus arithmetic is denoted by the operator MOD, which yields the
|
|
integer value that is the remainder of an integer division.
|
|
.br
|
|
The order in which operators are performed can be changec with parentheses.
|
|
.SH
|
|
Relational
|
|
.LP
|
|
The relational operators in order of precedence, are:
|
|
.DS
|
|
= Equality
|
|
<> Inequality
|
|
< Less than
|
|
> Greater than
|
|
<= Less than or equal to
|
|
>= Greater than or equal to
|
|
.DE
|
|
The relational operators are used to compare two values and returns
|
|
either "true" (-1) or "false" (0) (See IF statement).
|
|
The precedence of the relational operators is lower
|
|
then the arithmetic operators.
|
|
.SH
|
|
Logical
|
|
.LP
|
|
The logical operators performs tests on multiple relations, bit manipulations,
|
|
or Boolean operations.
|
|
The logical operators returns a bitwise result ("true" or "false").
|
|
In an expression, logical operators are performed after the relational and
|
|
arithmetic operators.
|
|
The logical operators work by converting their operands to signed
|
|
two-complement integers in the range -32768 to 32767.
|
|
.DS
|
|
NOT Bitwise negation
|
|
AND Bitwise and
|
|
OR Bitwise or
|
|
XOR Bitwise exclusive or
|
|
EQV Bitwise equivalence
|
|
IMP Bitwise implies
|
|
.DE
|
|
.SH
|
|
Functional
|
|
.LP
|
|
A function is used in an expression to call a system or user defined
|
|
function.
|
|
A list of predefined functions is presented in chapter 3.
|
|
.SH
|
|
String operations
|
|
.LP
|
|
Strings can be concatenated by using +. Strings can be compared with
|
|
the relational operators. String comparison is performed in lexicographic
|
|
order.
|
|
.NH 2
|
|
ERROR MESSAGES
|
|
.LP
|
|
The occurence of an error results in termination of the program
|
|
unless an ON....ERROR statement has been encountered.
|
|
.NH 1
|
|
B-EM STATEMENTS
|
|
.LP
|
|
This chapter describes the statements available within the BASIC-EM
|
|
compiler. Each description is formatted as follows:
|
|
.Sy
|
|
Shows the correct syntax for the statement. See introduction of
|
|
syntax notation above.
|
|
.PU
|
|
Describes the purpose and details of the instructions.
|
|
.RM
|
|
Describes special cases, deviation from Microsoft BASIC etc.
|
|
.LP
|
|
.NH 2
|
|
CALL
|
|
.Sy
|
|
CALL <variable name>[(<argument list>)]
|
|
.PU
|
|
The CALL statement provides the means to execute procedures
|
|
and functions written in another language included in the
|
|
Amsterdam Compiler Kit.
|
|
The argument list consist of (subscripted) variables.
|
|
The BASIC compiler pushes the address of the arguments on the stack in order
|
|
of encounter.
|
|
.RM
|
|
Not yet available
|
|
.NH 2
|
|
CLOSE
|
|
.Sy
|
|
CLOSE [[#]<file number>[,[#]<file number...>]]
|
|
.PU
|
|
To terminate I/O on a disk file.
|
|
<file number> is the number associated with the file
|
|
when it was OPENed (See OPEN). Ommission of parameters results in closing
|
|
all files.
|
|
.sp
|
|
The END statement and STOP statement always issue a CLOSE of
|
|
all files.
|
|
.NH 2
|
|
DATA
|
|
.Sy
|
|
DATA <list of constants>
|
|
.PU
|
|
DATA statements are used to construct a data bank of values that are
|
|
accessed by the program's READ statement.
|
|
DATA statements are non-executable,
|
|
the data items are assembled in a data file by the BASIC compiler.
|
|
This file can be replaced, provided the layout remains
|
|
the same (otherwise the RESTORE won't function properly).
|
|
.sp
|
|
The list of data items consists of numeric and string constants
|
|
as discussed in section 1.
|
|
Moreover, string constants starting with a letter and not
|
|
containing blancs, newlines, commas, colon need not be enclosed with
|
|
the string quotes.
|
|
.sp
|
|
DATA statements can be reread using the RESTORE statement.
|
|
.NH 2
|
|
DEF FN
|
|
.Sy
|
|
DEF FN<name> [(<parameterlist>)]=<expression>
|
|
.PU
|
|
To define and name a function that is written by the user.
|
|
<name> must be an identifier and should be preceded by FN,
|
|
which is considered integral part of the function name.
|
|
<expression> defines the expression to be evaluated upon function call.
|
|
.sp
|
|
The parameter list is comprised of a comma separated
|
|
list of variable names, used within the function definition,
|
|
that are to replaced by values upon function call.
|
|
The variable names defined in the parameterlist, called formal
|
|
parameters, do not affect the definition and use of variables
|
|
defined with the same name in the rest of the BASIC program.
|
|
.sp
|
|
A type declaration character may be suffixed to the function name to
|
|
designate the data type of the function result.
|
|
.NH 2
|
|
DEFINT/SNG/DBL/STR
|
|
.Sy
|
|
DEF<type> <range of letters>
|
|
.PU
|
|
Any undefined variable starting with the letter included in the range of
|
|
letters is declared of type <type> unless a type declaration character
|
|
is appended.
|
|
The range of letters is a comma separated list of characters and
|
|
character ranges (<letter>-<letter>).
|
|
.NH 2
|
|
DIM
|
|
.Sy
|
|
DIM <list of subscripted variable>
|
|
.PU
|
|
The DIM statement allocates storage for subscripted variables.
|
|
If an undefined subscripted variable is used
|
|
the maximum value of the array subscript(s) is assumed to be 10.
|
|
A subscript out of range is signalled by the program (when RCK works)
|
|
The minimum subscript value is 0, unless the OPTION BASE statement has been
|
|
encountered.
|
|
.sp
|
|
All variables in a subscripted variable are initially zero.
|
|
.sp
|
|
BUG. Multi-dimensional arrays MUST be defined.
|
|
.NH 2
|
|
END
|
|
.Sy
|
|
END
|
|
.PU
|
|
END terminates a BASIC program and returns to the UNIX shell.
|
|
An END statement at the end of the BASIC program is optional.
|
|
.NH 2
|
|
ERR and ERL
|
|
.PU
|
|
Whenever an error occurs the variable ERR contains the
|
|
error number and ERL the BASIC line where the error occurred.
|
|
The variables are usually used in error handling routines
|
|
provided by the user.
|
|
.NH 2
|
|
ERROR
|
|
.Sy
|
|
ERROR <integer expression>
|
|
.PU
|
|
To simulate the occurrence of a BASIC error.
|
|
To define your own error code use a value not already in
|
|
use by the BASIC runtime system.
|
|
The list of error messages currently in use
|
|
can be found in appendix B.
|
|
.NH 2
|
|
FIELD
|
|
.PU
|
|
To be implemented.
|
|
.NH 2
|
|
FOR...NEXT
|
|
.Sy
|
|
FOR <variable>= <low>TO<high>[STEP<size>]
|
|
.br
|
|
......
|
|
.br
|
|
NEXT [<variable>][,<variable>...]
|
|
.PU
|
|
The FOR statements allows a series of statements to be performed
|
|
repeatedly. <variable> is used as a counter. During the first
|
|
execution pass it is assigned the value <low>,
|
|
an arithmetic expression. After each pass the counter
|
|
is incremented with the step size <size>, an expression.
|
|
Ommission of the step size is intepreted as an increment of 1.
|
|
Execution of the program lines specified between the FOR and the NEXT
|
|
statement is terminated as soon as <low> is greater than <high>
|
|
.sp
|
|
The NEXT statement is labeled with the name(s) of the counter to be
|
|
incremented.
|
|
.sp
|
|
The body of the FOR statement is skipped when the initial value of the
|
|
loop times the sign of the step exceeds the value of the highest value
|
|
times the sign of the step.
|
|
.sp
|
|
The variables mentioned in the NEXT statement may be ommitted, in which case
|
|
the variable of increment the counter of the most recent FOR statement.
|
|
If a NEXT statement is encountered before its corresponding FOR statement,
|
|
the error message "NEXT without FOR" is generated.
|
|
.NH 2
|
|
GET
|
|
.Sy
|
|
GET [#]<file number>[, <record number>]
|
|
.PU
|
|
To be implemented.
|
|
.NH 2
|
|
GOSUB...RETURN
|
|
.Sy
|
|
GOSUB <line number
|
|
...
|
|
.br
|
|
RETURN
|
|
.PU
|
|
The GOSUB statement branches to the first statement of a subroutine.
|
|
The RETURN statement cause a branch back to the statement following the
|
|
most recent GOSUB statement.
|
|
A subroutine may contain more than one RETURN statement.
|
|
.sp
|
|
Subroutines may be called recursively.
|
|
Nesting of subroutine calls is limited, upon exceeding the maximum depth
|
|
the error message "XXXXX" is displayed.
|
|
.NH 2
|
|
GOTO
|
|
.Sy
|
|
GOTO <line number>
|
|
.PU
|
|
To branch unconditionally to a specified line in the program.
|
|
If <line number> does not exists, the compilation error message
|
|
"Line not defined" is displayed.
|
|
.RM
|
|
Microsoft BASIC continues at the first line
|
|
equal or greater then the line specified.
|
|
.NH 2
|
|
IF...THEN
|
|
.Sy
|
|
.br
|
|
IF <expression> THEN {<statements>|<line number>}
|
|
[ELSE {<statements>|<line number>}]
|
|
.br
|
|
.Sy
|
|
IF <expression> GOTO <line number>
|
|
[ELSE {<statements>|<line number>}]
|
|
.PU
|
|
The IF statement is used
|
|
to make a decision regarding the program flow based on the
|
|
result of the expressions.
|
|
If the expression is not zero, the THEN or GOTO clause is
|
|
executed. If the result of <expression> is zero, the THEN or
|
|
GOTO clause is ignored and the ELSE clause, if present is
|
|
executed.
|
|
.br
|
|
IF..THEN..ELSE statements may be nested.
|
|
Nesting is limited by the length of the line.
|
|
The ELSE clause matches with the closests unmatched THEN.
|
|
.sp
|
|
When using IF to test equality for a value that is the
|
|
result of a floating point expression, remember that the
|
|
internal representation of the value may not be exact.
|
|
Therefore, the test should be against a range to
|
|
handle the relative error.
|
|
.RM
|
|
Microsoft BASIC allows a comma before THEN.
|
|
.NH 2
|
|
INPUT
|
|
.Sy
|
|
INPUT [;][<"prompt string">;]<list of variables>
|
|
.PU
|
|
An INPUT statement can be used to obtain values from the user at the
|
|
terminal.
|
|
When an INPUT statement is encountered a question mark is printed
|
|
to indicate the program is awaiting data.
|
|
IF <"prompt string"> is included, the string is printed before the
|
|
the question mark. The question mark is suppressed when the prompt
|
|
string is followed by a comma, rather then a semicolon.
|
|
.sp
|
|
For each variable in the variable a list a value should be supplied.
|
|
Data items presented should be separated by a comma.
|
|
.sp
|
|
The type of the variable in the variable list must aggree with the
|
|
type of the data item entered. Responding with too few or too many
|
|
data items causes the message "?Redo". No assignment of input values
|
|
is made until an acceptable response is given.
|
|
.RM
|
|
The option to disgard the carriage return with the semicolon after the
|
|
input symbol is not yet implemented.
|
|
.NH 2
|
|
INPUT [#]
|
|
.Sy
|
|
INPUT #<file number>,<list of variables>
|
|
.PU
|
|
The purpose of the INPUT# statement is to read data items from a sequential
|
|
file and assign them to program variables.
|
|
<file number> is the number used to open the file for input.
|
|
The variables mentioned are (subscripted) variables.
|
|
The type of the data items read should aggree with the type of the variables.
|
|
A type mismatch results in the error message "XXXXX".
|
|
.sp
|
|
The data items on the sequential file are separated by commas and newlines.
|
|
In scanning the file, leading spaces, new lines, tabs, and
|
|
carriage returns are ignored. The first character encountered
|
|
is assumed to be the state of a new item.
|
|
String items need not be enclosed with double quotes, provided
|
|
it does not contain spaces, tabs, newlines and commas,
|
|
.RM
|
|
Microsoft BASIC won't assign values until the end of input statement.
|
|
This means that the user has to supply all the information.
|
|
.NH 2
|
|
LET
|
|
.Sy
|
|
[LET]<variable>=<expression>
|
|
.PU
|
|
To assign the value of an expression to a (subscribted) variable.
|
|
The type convertions as dictated in section 1.X apply.
|
|
.NH 2
|
|
LINE INPUT
|
|
.Sy
|
|
LINE INPUT [;][<"prompt string">;]<string variable>
|
|
.PU
|
|
An entire line of input is assigned to the string variable.
|
|
See INPUT for the meaning of the <"prompt string"> option.
|
|
.NH 2
|
|
LINE INPUT [#]
|
|
.Sy
|
|
LINE INPUT #<file number>,<string variable>
|
|
.PU
|
|
Read an entire line of text from a sequential file <file number>
|
|
and assign it to a string variable.
|
|
.NH 2
|
|
LSET and RSET
|
|
.PU
|
|
To be implemented
|
|
.NH 2
|
|
MID$
|
|
.Sy
|
|
MID$(<string expr1>,n[,m])=<string expr2>
|
|
.PU
|
|
To replace a portion of a string with another string value.
|
|
The characters of <string expr> replaces characters in <string expr1>
|
|
starting at position n. If m is present, at most m characters are copied,
|
|
otherwise all characters are copied.
|
|
However, the string obtained never exceeds the length of string expr1.
|
|
.NH 2
|
|
ON ERROR GOTO
|
|
.Sy
|
|
ON ERROR GOTO <line number>
|
|
.PU
|
|
To enable error handling within the BASIC program.
|
|
An error may result from arithmetic errors, disk problems, interrupts, or
|
|
as a result of the ERROR statement.
|
|
After printing an error message the program is continued at the
|
|
statements associated with <line number>.
|
|
.sp
|
|
Error handling is disabled using ON ERROR GOTO 0.
|
|
Subsequent errors result in an error message and program termination.
|
|
.NH 2
|
|
ON...GOSUB and ON ...GOTO
|
|
.Sy
|
|
ON <expression> GOSUB <list of line numbers>
|
|
ON <expression> GOTO <list of line numbers>
|
|
.PU
|
|
To branch to one of several specified line numbers or subroutines, based
|
|
on the result of the <expression>. The list of line numbers are considered
|
|
the first, second, etc alternative. Branching to the first occurs when
|
|
the expression evaluates to one, to the second alternative on two, etc.
|
|
If the value of the expression in zero or greater than the number of alternatives, processing continues at the first statement following the ON..GOTO
|
|
(ON GOSUB) statement.
|
|
When the expression results in a negative number the
|
|
an "Illegal function call" error occurs.
|
|
.NH 2
|
|
OPEN
|
|
.NH 2
|
|
OPTION BASE
|
|
.Sy
|
|
OPTION BASE n
|
|
.PU
|
|
To declare the lower bound of subsequent array subscripts as either
|
|
0 or 1. The default lower bound is zero.
|
|
.NH 2
|
|
POKE
|
|
.Sy
|
|
POKE <expr1>,<expr2>
|
|
.PU
|
|
To poke around in memory. The use of this statement is not recommended,
|
|
because it requires full understanding of both
|
|
the implementation of the Amsterdam
|
|
Compiler Kit and the hardware characteristics.
|
|
.NH 2
|
|
PRINT [USING]
|
|
.NH 2
|
|
PUT
|
|
.PU
|
|
To be implemented
|
|
.NH 2
|
|
RANDOMIZE
|
|
.Sy
|
|
RANDOMIZE [<expression>]
|
|
.PU
|
|
To reset the random seed. When the expression is ommitted, the system
|
|
will ask for a value between -32768 and 32767.
|
|
The random number generator returns the same sequence of values provided
|
|
the same seed is used.
|
|
.NH 2
|
|
READ
|
|
.Sy
|
|
READ <list of variables>
|
|
.PU
|
|
To read values from the DATA statements and assign them to variables.
|
|
The type of the variables should match to the type of the items being read,
|
|
otherwise a "Syntax error" occurs.
|
|
.NH 2
|
|
REM
|
|
.Sy
|
|
REM <remark>
|
|
.PU
|
|
To include explantory information in a program.
|
|
The REM statements are not executed.
|
|
A single quote has the same effect as : REM, which
|
|
allows for the inclusion of comment at the end of the line.
|
|
.RM
|
|
Microsoft BASIC does not allow REM statements as part of
|
|
DATA lines.
|
|
.NH 2
|
|
RESTORE
|
|
.Sy
|
|
RESTORE [<line number>]
|
|
.PU
|
|
To allow DATA statements to be re-read from a specific line.
|
|
After a RESTORE statement is executed, the next READ accesses
|
|
the first item of the DATA statements.
|
|
If <line number> is specified, the next READ accesses the first
|
|
item in the specified line.
|
|
.sp
|
|
Note that data statements result in a sequential datafile generated
|
|
by the compiler, being read by the read statements.
|
|
This data file may be replaced using the operating system functions
|
|
with a modified version, provided the same layout of items
|
|
(same number of lines and items per line) is used.
|
|
.NH 2
|
|
STOP
|
|
.Sy
|
|
STOP
|
|
.PU
|
|
To terminate the execution of a program and return to the operating system
|
|
command interpreter. A STOP statement results in the message "Break in line
|
|
???"
|
|
.NH 2
|
|
SWAP
|
|
.Sy
|
|
SWAP <variable>,<variable>
|
|
.PU
|
|
To exchange the values of two variables.
|
|
.NH 2
|
|
TRON/TROFF
|
|
.Sy
|
|
TRON
|
|
.Sy
|
|
TROFF
|
|
.PU
|
|
As an aid in debugging the TRON statement results in a program
|
|
listing each line being interpreted. TROFF disables generation of
|
|
this code.
|
|
.NH 2
|
|
WHILE...WEND
|
|
.Sy
|
|
WHILE <expression>
|
|
.....
|
|
WEND
|
|
.PU
|
|
To execute a series of BASIC statements as long as a conditional expression
|
|
is true. WHILE...WEND loops may be nested.
|
|
.NH 2
|
|
WRITE
|
|
.Sy
|
|
WRITE [<list of expressions>]
|
|
.PU
|
|
To write data at the terminal in DATA statement layout conventions.
|
|
The expressions should be separated by commas.
|
|
.NH 2
|
|
WRITE #
|
|
.Sy
|
|
WRITE #<file number> ,<list of expressions>
|
|
.PU
|
|
To write a sequential data file, being opened with the "O" mode.
|
|
The values are being writting using the DATA statements layout conventions.
|
|
.NH
|
|
FUNCTIONS
|
|
.LP
|
|
.IP ABS(X) 12
|
|
Returns the absolute value of expression X
|
|
.IP ASC(X$) 12
|
|
Returns the numeric value of the first character of the string.
|
|
If X$ is not initialized an "Illegal function call" error
|
|
is returned.
|
|
.IP ATN(X) 12
|
|
Returns the arctangent of X in radians. Result is in the range
|
|
of -pi/2 to pi/2.
|
|
.IP CDBL(X) 12
|
|
Converts X to a double precision number.
|
|
.IP CHR$(X) 12
|
|
Converts the integer value X to its ASCII character.
|
|
X must be in the range of 0 to 127.
|
|
It is used for cursor addressing and generating bel signals.
|
|
.IP CINT(X) 12
|
|
Converts X to an integer by rounding the fractional portion.
|
|
If X is not in the range -32768 to 32767 an "Overflow"
|
|
error occurs.
|
|
.IP COS(X) 12
|
|
Returns the cosine of X in radians.
|
|
.IP CSNG(X) 12
|
|
Converts X to a double precision number.
|
|
.IP CVI(<2-bytes>) 12
|
|
Convert two byte string value to integer number.
|
|
.IP CVS(<4-bytes>) 12
|
|
Convert four byte string value to single precision number.
|
|
.IP CVD(<8-bytes>) 12
|
|
Convert eight byte string value to double precision number.
|
|
.IP EOF[(<file-number>)] 12
|
|
Returns -1 (true) if the end of a sequential file has been reached.
|
|
.IP EXP(X) 12
|
|
Returns e(base of natural logarithm) to the power of X.
|
|
X should be less then 10000.0.
|
|
.IP FIX(X) 12
|
|
Returns the truncated integer part of X. FIX(X) is
|
|
equivalent to SGN(X)*INT(ABS(X)).
|
|
The major difference between FIX and INT is that FIX does not
|
|
return the next lower number for negative X.
|
|
.IP HEX$(X) 12
|
|
Returns the string which represents the hexadecimal value of
|
|
the decimal argument. X is rounded to an integer using CINT
|
|
before HEX$ is evaluated.
|
|
.IP INT(X) 12
|
|
Returns the largest integer <= X.
|
|
.IP INPUT$(X[,[#]Y]) 12
|
|
Returns the string of X characters read from the terminal or
|
|
the designated file.
|
|
.IP LEX(X$) 12
|
|
Returns the number of characters in the string X$.
|
|
Non printable and blancs are counted too.
|
|
.IP LOC(<file\ number>) 12
|
|
For sequential files LOC returns
|
|
position of the read/write head, counted in number of bytes.
|
|
For random files the function returns the record number just
|
|
read or written from a GET or PUT statement.
|
|
If nothing was read or written 0 is returned.
|
|
.IP LOG(X) 12
|
|
Returns the natural logarithm of X. X must be greater than zero.
|
|
.IP MID$(X,I,[J]) 12
|
|
To be implemented.
|
|
.IP MKI$(X) 12
|
|
Converts an integer expression to a two-byte string.
|
|
.IP MKS$(X) 12
|
|
Converts a single precision expression to a four-byte string.
|
|
.IP MKD$(X) 12
|
|
Converts a double precision expression to a eight-byte string.
|
|
.IP OCT$(X) 12
|
|
Returns the string which represents the octal value of the decimal
|
|
argument. X is rounded to an integer using CINT before OCTS is evaluated.
|
|
.IP PEEK(I) 12
|
|
Returns the byte read from the indicated memory. (Of limited use
|
|
in the context of ACK)
|
|
.IP POS(I) 12
|
|
Returns the current cursor position. To be implemented.
|
|
.IP RIGHT$(X$,I)
|
|
Returns the right most I characters of string X$.
|
|
If I=0 then the empty string is returned.
|
|
.IP RND(X) 12
|
|
Returns a random number between 0 and 1. X is a dummy argument.
|
|
.IP SGN(X) 12
|
|
If X>0 , SGN(X) returns 1.
|
|
.br
|
|
if X=0, SGN(X) returns 0.
|
|
.br
|
|
if X<0, SGN(X) returns -1.
|
|
.IP SIN(X) 12
|
|
Returns the sine of X in radians.
|
|
.IP SPACE$(X) 12
|
|
Returns a string of spaces length X. The expression
|
|
X is rounded to an integer using CINT.
|
|
.IP STR$(X)
|
|
Returns the string representation value of X.
|
|
.IP STRING$(I,J) 12
|
|
Returns thes string of length Iwhose characters all
|
|
have ASCII code J. (or first character when J is a string)
|
|
.IP TAB(I) 12
|
|
Spaces to position I on the terminal. If the current
|
|
print position is already beyond space I,TAB
|
|
goes to that position on the next line.
|
|
Space 1 is leftmost position, and the rightmost position
|
|
is width minus 1. To be used within PRINT statements only.
|
|
.IP TAN(X) 12
|
|
Returns the tangent of X in radians. If TAN overflows
|
|
the "Overflow" message is displayed.
|
|
.IP VAL(X$) 12
|
|
Returns the numerical value of string X$.
|
|
The VAL function strips leading blanks and tabs from the
|
|
argument string.
|
|
.SH
|
|
APPENDIX A DIFFERENCES WITH MICROSOFT BASIC
|
|
.LP
|
|
The following list of Microsoft commands and statements are
|
|
not recognized by the compiler.
|
|
.DS
|
|
SPC
|
|
USR
|
|
VARPTR
|
|
AUTO
|
|
CHAIN
|
|
CLEAR
|
|
CLOAD
|
|
COMMON
|
|
CONT
|
|
CSAVE
|
|
DELETE
|
|
EDIT
|
|
ERASE
|
|
FRE
|
|
KILL
|
|
LIST
|
|
LLIST
|
|
LOAD
|
|
LPRINT
|
|
MERGE
|
|
NAME
|
|
NEW
|
|
NULL
|
|
RENUM
|
|
RESUME
|
|
RUN
|
|
SAVE
|
|
WAIT
|
|
WIDTH LPRINT
|
|
.DE
|
|
Some statements are in the current implementation not available,
|
|
but will be soon. These include:
|
|
.DS
|
|
CALL
|
|
DEFUSR
|
|
FIELD
|
|
GET
|
|
INKEY
|
|
INPUT$
|
|
INSTR$
|
|
LEFT$
|
|
LSET
|
|
RSET
|
|
PUT
|
|
.DE
|